Air oxygen meter GMH 3691

Hand-held device

GMH 3691

Features:
  • Double display for oxygen and temperature
  • Measured units: O2-concentration and O2-partial pressure
  • Alarm detector with integrated horn
  • Automatic temperature compensation
  • Min-/max-value memory, hold function
  • Serial interface, can be connected to RS232 or USB interface of a PC
  • Connectable to bus system (up to 5 devices can be connected to one PC interface)
  • Battery and D.C. operation possible
  • Operating control: 6 membrane keys for ON/OFF switch, selection of measurement range, min- and max- value memory, hold-function, calibration etc.
  • Calibration:
    • 1-point-calibration: simple quick calibration in atmospheric air (press button to compensate unit to 20,9%).
    • 2-point-calibration: first point at atmospheric air (20,9%), second point freely selectable.
Measurement ranges  
Oxygen concentration: 0,0...100,0% O2 (gaseous)
Partial oxygen pressure: 0...1100 hPa O2
Temperature: -5,0...+50,0°C
   
Accuracy (device) at nominal temperature = +25°C
Oxygen concentration: ± 0,1% ± 1 Digit
Partial oxygen pressure: ± 1 hPa
Temperature: ± 0,1°C ± 1 Digit
   
Display: two 4-digit LCDs (12,4 mm or 7 mm high)
Operating temperature: 0...+50°C
Relative humidity: 0...95% RH (non-condensing)
Storage temperature: -20°C...+70°C
Battery:

9V battery type IEC 6F22
additional d.c. connector for external 10,5-12 V direct voltage supply existing

Power consumption: approx. 1,5 mA
Automatic-Off-Function: 1...120 min (can be switched off)
Housing: impact resistant ABS, front side IP65
Dimensions: 142 x 71 x 26 mm
Weight: approx. 160 g (incl. battery)

Sensors for oxygen measurements

 

Closed oxygen sensors GGO 369 S and GGO 370

• suitable for under and over pressure
• for using in gas-tight systems
• dimensions: approx. Ø 36 mm x 95 mm (150 mm incl. bend protection)
• weight: approx. 135 g

Application: Suitable for measuring in normal atmosphere and in systems without or with slight under or over pressure. The sensor type features a screw thread and can be built in gas-tight in almost every system directly resp. with tube-adapter.
The acid electrolyte of the GGO 369 S guarantees that the sensor could not be influenced by CO2.


 

Open oxygen sensors GOO 369 S and GOO 370

• suitable for air- or gas-stream
• quick temperature compensation
• dimensions: approx. Ø 40 mm x 105 mm (160 mm incl. bend protection)
• weight: approx. 145 g

Application: Because of the special sensor construction the measuring gas streams optimally around the sensor and escapes through holes in the housing into the air. No pressure build-up at slight streaming of the probe, that falsify the result of measurement. Particularly suitable for measuring of gas out of gas-bottle etc. Even measuring indoor-gas concentration is possible.
The acid electrolyte of the GOO 369 S guarantees that the sensor could not be influenced by CO2.

Technical specifications
  GGO 369 S and GOO 369 S GGO 370 and GOO 370
Application: CO2 containing gases universal applications, diving
Specific features: acidic electrolyte

stronger membrane
coated electronics
temperature compensation

Measurement ranges    
Partial oxygen pressure: 0...1000 hPa O2 0...1100 hPa O2
Oxygen concentration: 0,0...25,0% O2 (gaseous) 0,0..100,0% O2
Temperature: 0,0...+50,0°C 0,0...+45,0°C
     
Sensor: partial oxygen pressure sensor  
Response time t90: < 15 sec < 10 sec
Cross sensitivities: Signal of <0,002% O2
100% CO2, 100% CO, 3000 ppm NO in N2,1000 ppm H2 in N2, 100% C3H8, 2000 ppm H2S in N2, 2000 ppm SO2 in N2, 1000 ppm Benzene in N2
 
Working temperature: 0...+45°C 0...+50°C
Relative humidity:
0...95% rF (non-condensing)
Nominal sensor life:
approx. 2 years at nominal condition
Operating pressure:
0,5 to 2,0 bar absolute
Connection:
approx. 1 m cable with Mini-DIN-plug
Storage temperature:
-15°C...+60°C
Housing:
with M16x 1-screw thread (sensor can be connected to line tubes by means of an additional adapter

Air oxygen meter GMH 3691 (without sensor)
154,00 €
Accessories  
Interface converter for RS232, electrical isolated (GRS 3100)
47,30 €
Interface converter for RS232, with 5 connection points for the connection of 5 GMH 3691 to one PC (GRS 3105)
100,50 €
Interface converter for USB, electrical isolated (USB 3100)
47,30 €
D.c. connector for external 10,5-12 V direct voltage supply (GNG 10/3000)
21,10 €
Case (GKK 3000)
14,50 €
Device protection bag with cut-out for probe connection (ST-R1)
22,50 €
Replacement battery 9V (GB 9 V)
1,70€
Oxygen sensors
 
Oxygen sensor GGO 369 S, closed sensor with acid electrolyte, incl. tube adapter - for CO2 containing gases
149,20 €
Oxygen sensor GOO 369 S, open sensor with acid electrolyte, incl. tube adapter - for CO2 containing gases
164,60 €
Oxygen sensor GGO 370, closed sensor, incl. tube adapter and T-piece - for universal applications, diving
111,30 €
Oxygen sensor GOO 370, open sensor, incl. tube adapter and T-piece - for universal applications, diving
126,30 €
Cable length 4 m
17,00 €
Cable length 10 m
26,50 €
Replacement sensor element for GGO 369 S and GOO 369 S (GOEL 369 S)
99,60 €
Replacement sensor element for GGO 370 and GOO 370 (GOEL 370)
63,10 €
Replacement tube adapter M16 x 1, for tubes with an inner-diameter of 15 mm (ESA 369)
3,00 €
order

Terms of sales and delivery

Products on stock are usually sent out within one week. Nevertheless, please order as early as possible. Transport is normally by UPS standard (±2-3 days within Europe), shipping and packing are billed with € 5,- + shipping costs, from € 200,- only the real shipping costs.
All prices are exclusive VAT. Payments can be made within 30 days by bank transfer, within 14 days with 3% discount. All prices are subject to change without prior notice according to our terms and conditions. Check our website for actual information.

Seite drucken print this page

Long Life for Art | Christoph Waller | Hauptstr. 47 | D-79356 Eichstetten | Tel. +49(0) 7663 608 99-0 | Fax -20