Gebäudeklima in Museen
Unterrichtseinheit an der Universität für Angewandte Kunst, Wien, (Text in Bearbeitung)
5.10 Bibliographie
Wichtige Referenzen sind fett gedruckt!
neu: Henderson, Jane (ed.): Conservation Matters in Wales: Challenging buildings: The search for solutions, Cardiff 2006, verschiedene Vorträge zu Museumsgebäuden www.mdaf.pwp.blueyonder.co.uk/conference/images/cons_in_wales_english.pdf
- Bellardo, Lew: Low Energy, Low Technology, Low Toxicity Approaches
to Preservation, http://palimpsest.stanford.edu/byorg/abbey/an/an19/an19-1/
Recommendations for archives that lack adequate and affordable energy
supplies and whose acces to technology is severely limited.
- Brune Luftbefeuchtung Proklima GmbH, Schwarzacher Str. 74848 Aglasterhausen,
Tel: 06262 - 5454, Fax: 3255, Luftbefeuchter / Humidifiers, www.brune.info.de
- Defensor s. Schäfer.
- DryKor: www.drycor.com
Efficient electric
dehumidifiers based on lithium chloride.
- Fachinstitut Gebäude-Klima e.V.: Raumklima in Museen, Eine FGK-Informationsschrift,
Bietigheim -Bissingen 1998 oder 1999.
- Fischer, Konrad: Altbau und Denkmalpflege Informationen, 1400 Internetseiten
Fachwissen, wenn auch bisweilen ketzerisch und mit nicht immer stichhaltigen
Argumenten vorgetragen.
http://www.konrad-fischer-info.de/index.htm
- Die
Temperierung der Gebäude-Hüllfächen
- Aufsteigende Feuchte
- Großeschmidt, Henning: Das temperierte Haus: sanierte Architektur
und "Großvitrine", 14 Jahre besucherfreundliche Schadensprävention mit
Temperieranlagen, in: Aspekte der Museumsarbeit in Bayern, Band 5, 1996, S. 101 - 116.
- Großeschmidt, Henning: Klimastabilisierung als Grundlage sachgerechter
Bewahrung Oder: Das temperierte Haus, sanierte Architektur und Großvitrine,
in: Museum Aktuell, Sept. 1998, S. 1300-1303.
- Hilbert, Günter S.: Sammlungsgut in Sicherheit, Berlin 1996, insbesondere S. 124 - 211.
- Huber, Alfons: Problemzone Fenster, Beitrag in: Museum Microclimates, Konferenz Kopenhagen 2007, siehe http://www.natmus.dk/graphics/konferencer_mm/microclimates/pdf/huber.pdf
- Hygrometric Dr. Brokmann, Hinterm Rasen 4, 98693 Ilmenau, Tel: 03677
62711, Fax: 62710. Lüftungsindikator "Lindi".
- Krah & Grote Messtechnik, Fichtenstr. 23, 85649 Hofolding, Tel: 08104
- 666535, Fax. 666536, www.Krah-Grote.de
Thermographie, Datenlogger und Meßsysteme für Klima und Licht, Mietservice.
- Massari, Ippolito: Damp Buildings Old and New, ICCROM 1993, pp. 94-97.
- Oreszczyn, T. et al: Comparative Study of air-conditioned and non
air-conditioned museums, in: Preventive Conservation, IIC Congress Ottawa 1994, Preprints, p. 144-148.
- Padfield, Tim: The physics of the museum environment: www.natmus.dk/cons/tp/index/:
- humidity buffering by museum walls,
- Condensation in the walls of humidified museums,
- Casting mud in the debate about climate standards in museums,
- buffering the indoor relative humidity with porous walls,
- humidity buffering by porous, absorbent insulation,
- how air conditioning works
- Park; Sharon C.: Heating, Ventilating, and Cooling Historic Buildings:
Problems and Recommend Approaches, http://www2.cr.nps.gov/tps/briefs/brief24.htm
Underscores the importance of careful planning in order to balance preservation
objectives with the interior climate needs of the building. 14 pages.
1991.
- Park, Sharon C.: Holding the Line: Controlling Unwanted Moisture
in Historic Buildings.
Outlines a way to diagnose moisture problems and choose remedial treatments
within a historic preservation context. Considers the five major sources
of moisture, including the exterior building envelope, ground moisture
infiltration, interior condensation, leaking pipes, and moisture from
cleaning or construction. Provides guidance on managing moisture deterioration,
repairing and maintaining historic building materials, and correcting
common problem areas. Includes charts on types of diagnostic tools,
recommended treatments and treatments that should always be avoided.
16 pages. 1996.
- Pistohl, Wolfram: Handbuch der Gebäudetechnik. Planungsgrundlagen und Beispiele. Band 1, 4. Aufl. 2002.
- Pistohl, Wolfram: Handbuch der Gebäudetechnik. Planungsgrundlagen und Beispiele. Band 2, 4. Aufl. 2002.
- Schäfer Raumlufttechnik, Inh. Hauke Kock, Vertrieb von
Luftbefeuchtern und -entfeuchtern, speziell auch für Museen.
www.schaefer-raumlufttechnik.de
Humidifiers/dehumidifiers, different brands.
- Thatcher Ellis, R.: Getting Function from Design: Making Systems
Work www.nedcc.org/plam3/tleaf23.htm
Enthält viele Details, auf die bei der Planung und Abnahme von Klimaanlagen zu achten ist.
- Thomson, Gary: The Museum Environment, Butterworth, Oxford 1994.
- Zeller, Joachim: Luftdichtigkeit von Wohngebäuden, 1998, energieverlag@heidelberg-online.de
Further Links:
- http://palimpsest.stanford.edu/bytopic/environment/
- Practical Guide to Museums and Historic Renovation at http://resourcecenter.ashrae.org/store/ashrae/newstore.cgi
- The following articles are available on-line in PDF format:
- 1. HVAC at 18th-Century Colonial Williamsburg by Clyde Delmar Kestner, P.E.
- 2. Air Distribution for Large Spaces by Dan Int-Hout and Lean Kostra
- 3. Filters and Filtration by Timothy J. Robinson and Alan E. Ouellet
- 4. What Makes Records Deteriorate by Paul N. Banks
- 5. Temperature and Relative Humidity Effects on the Mechanical and Chemical Stability of Collectors
by Marion F. Mecklenburg, Ph.D., and Charles S. Tumosa, Ph.D.
- 6. Understanding What Humidity Does and Why by Kenneth M. Elovitz, P.E.
Long Life for Art | Christoph Waller | Hauptstr. 47 | D-79356 Eichstetten | Tel. +49(0) 7663 608 99-0 | Fax -20
E-Mail:
info@llfa.de, Web:
www.llfa.de, © c.waller